industrial hot water heater                                  

direct contact hot water heater
   
  QW Awards  Menu                 Save 40% a Year on Fuel Cost        

 

CALL

1-918-241-8880

FOR MORE

INFORMATION


  

 
 
QuikWater


8939 West 21st. St.
Sand Springs, OK 74063


Fax: 918-241-8718
 
 
  





Sales@QuikWater.com


















































  

Energy Effecient Water Heaters

Yes, we know, you see grandiose claims like this for products everyday. But we're not kidding. You CAN save this much with our Energy Efficient Hot Water Heaters, and we don't expect you to take that claim on faith. We're going to prove it to you. 

Below you will find a calculation that compares fuel costs for a typical boiler and a typical QuikWater unit. If you want to compute the exact savings for your operation, click on the Compute Expected Fuel Savings button below with Energy Conservation Hot Water Heaters.

We're happy to have you run through these calculations, because we know what answer you will find. Remarkable fuel savings, remarkable enough to have a measurable effect on anyone's bottom line. Numbers so good that many of our current customers don't want us to publicize the fact that they ARE QuikWater customers, because our water heating systems have given them a high-quality competitive advantage. 

Impressive as they are, the savings listed below are only the fuel savings you will see. Above that, typical QuikWater customers see savings in:

  • Reduced thermal losses
  • Chemical cost reduced to zero
  • Lower insurance as vessel is non-pressurized
  • Reduced maintenance
     

Hot water heater fuel savings


Plant total operating hours
 
Length in shift in hours 
(X)
8
Number of shifts per day
(X)
2
Number of operating days
(Equals)
312
  
 

TOTAL OPERATING HOURS

4160
 
               REQUIRED OUTPUT VOLUME IN GALLONS PER MINUTE 100
  
Required Temperature rise (Delta T)
 
Required Outlet Temperature 
(degrees F)
(Minus)
160
Inlet water Temperature 
(degrees F) 
(Equals)
60
REQUIRED TEMPERATURE 
RISE (degrees F)
 
100

PLANT'S FUEL COST RATE PER THOUSAND CUBIC FEET 
($/ MCF = ($/ therm X10))
 

$3.50

Plant's calculated Btu / Hr requirements using the following heating energy demand equation:        
 
gpm x 500 x temperature rise (DT) = mmBtu / Hr required
  

  QUIKWATER
     HEATERS      
  

   TYPICAL    
BOILER      

5 Required mmBtu / Hr

5

99% ESTIMATED HEATING UNIT THERMAL EFFICIENCIES
 
Hourly Fuel Cost
60%
5 mmBTU/HR
(X)
5
$3.50 $/ MCF $3.50
$17.5 / Hr (=) $17.5 / Hr
.99 (/)
Thermal Efficiency
(=)
.60
 $17.67 / Hr

FUEL COST PER HOUR

$29.16/ Hr
  
HOURLY COST SAVINGS:    $29.16/Hr 

- $17.67/Hr

__________________
$11.49/Hr
   
DAILY COST SAVINGS: $183.84
MONTHLY COST SAVINGS: $4,779.84
YEARLY COST SAVINGS:

$57,358.08


[Home] [Products] [Services] [Clients] [About] [Contact Us]